skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A computational implementation and comparison of several intensity modulated proton therapy treatment planning algorithms

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.2836954· OSTI ID:21036175
; ; ; ;  [1]
  1. Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, Florida 32610-0385 (United States)

The authors present a comparative study of intensity modulated proton therapy (IMPT) treatment planning employing algorithms of three-dimensional (3D) modulation, and 2.5-dimensional (2.5D) modulation, and intensity modulated distal edge tracking (DET) [A. Lomax, Phys. Med. Biol. 44, 185-205 (1999)] applied to the treatment of head-and-neck cancer radiotherapy. These three approaches were also compared with 6 MV photon intensity modulated radiation therapy (IMRT). All algorithms were implemented in the University of Florida Optimized Radiation Therapy system using a finite sized pencil beam dose model and a convex fluence map optimization model. The 3D IMPT and the DET algorithms showed considerable advantages over the photon IMRT in terms of dose conformity and sparing of organs at risk when the beam number was not constrained. The 2.5D algorithm did not show an advantage over the photon IMRT except in the dose reduction to the distant healthy tissues, which is inherent in proton beam delivery. The influences of proton beam number and pencil beam size on the IMPT plan quality were also studied. Out of 24 cases studied, three cases could be adequately planned with one beam and 12 cases could be adequately planned with two beams, but the dose uniformity was often marginally acceptable. Adding one or two more beams in each case dramatically improved the dose uniformity. The finite pencil beam size had more influence on the plan quality of the 2.5D and DET algorithms than that of the 3D IMPT. To obtain a satisfactory plan quality, a 0.5 cm pencil beam size was required for the 3D IMPT and a 0.3 cm size was required for the 2.5D and the DET algorithms. Delivery of the IMPT plans produced in this study would require a proton beam spot scanning technique that has yet to be developed clinically.

OSTI ID:
21036175
Journal Information:
Medical Physics, Vol. 35, Issue 3; Other Information: DOI: 10.1118/1.2836954; (c) 2008 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English

Similar Records

Influence of robust optimization in intensity-modulated proton therapy with different dose delivery techniques
Journal Article · Fri Jun 15 00:00:00 EDT 2012 · Medical Physics · OSTI ID:21036175

TH-A-BRE-01: The Status of Intensity Modulated Proton and Ion Therapy
Journal Article · Sun Jun 15 00:00:00 EDT 2014 · Medical Physics · OSTI ID:21036175

Proton Radiotherapy for Pediatric Central Nervous System Germ Cell Tumors: Early Clinical Outcomes
Journal Article · Sat Jan 01 00:00:00 EST 2011 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21036175