skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Correlation of PET standard uptake value and CT window-level thresholds for target delineation in CT-based radiation treatment planning

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
 [1];  [2];  [2];  [1];  [1]
  1. Department of Radiation Oncology, Nuclear Medicine Division, Loyola University Medical Center, Maywood, IL (United States)
  2. Department of Radiology, Nuclear Medicine Division, Loyola University Medical Center, Maywood, IL (United States)

Purpose: To develop standardized correlates of [{sup 18}F]fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) standard uptake value (SUV) to computed tomography (CT)-based window and levels. Methods and Materials: Nineteen patients with non-small-cell lung cancer who underwent imaging with positron emission tomography (PET) and CT were selected. A method of standardizing SUV within CT planning software was developed. A scale factor, determined by a sensitivity calibration of the PET scanner, converts voxel counts to activity per gram in tissue, allowing SUVs to be correlated to CT window and levels. A method of limiting interobserver variations was devised to enhance 'edges' of regions of interest based on SUV thresholds. The difference in gross tumor volumes (GTVs) based on CT, PET SUV {>=} 2.5, and regions of 40% maximum SUV were analyzed. Results: The mean SUV was 9.3. Mean GTV volumes were 253 cc for CT, 221 cc for SUV {>=} 2.5, and 97 cc for SUV40%Max. Average volume difference was -259% between {>=}2.5 SUV and CT and -162% between SUV40%Max and CT. Percent difference between GTV {>=} 2.5 SUV and SUV40%Max remained constant beyond SUV > 7. For SUVs 4-6, best correlation among SUV thresholds occurred at volumes near 90 cc. Mean percent change from GTVs contoured according to CT (GTV CT) was -260% for GTV2.5 and -162% for GTV40%Max. Using the SUV40%Max threshold resulted in a significant alteration of volume in 98% of patients, while the SUV2.5 threshold resulted in an alteration of volume in 58% of patients. Conclusions: Our method of correlating SUV to W/L thresholds permits accurate displaying of SUV in coregistered PET/CT studies. The optimal SUV thresholds to contour GTV depend on maximum tumor SUV and volume. Best correlation occurs with SUVs >6 and small volumes <100 cc. At SUVs >7, differences between the SUV threshold filters remain constant. Because of variability in volumes obtained by using SUV40%Max, we recommend using SUV {>=} 2.5 for radiotherapy planning in non-small-cell lung cancer.

OSTI ID:
20944721
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Vol. 67, Issue 3; Other Information: DOI: 10.1016/j.ijrobp.2006.09.039; PII: S0360-3016(06)03130-0; Copyright (c) 2007 Elsevier Science B.V., Amsterdam, Netherlands, All rights reserved; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
Country of Publication:
United States
Language:
English

Similar Records

Reproducibility of 'Intelligent' Contouring of Gross Tumor Volume in Non-Small-Cell Lung Cancer on PET/CT Images Using a Standardized Visual Method
Journal Article · Thu Jul 15 00:00:00 EDT 2010 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20944721

Increasing the Accuracy of Volume and ADC Delineation for Heterogeneous Tumor on Diffusion-Weighted MRI: Correlation with PET/CT
Journal Article · Tue Oct 01 00:00:00 EDT 2013 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20944721

Comparison of Tumor Volumes as Determined by Pathologic Examination and FDG-PET/CT Images of Non-Small-Cell Lung Cancer: A Pilot Study
Journal Article · Tue Dec 01 00:00:00 EST 2009 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20944721