We report the design and performance of the hybrid electromagnetic calorimeter consisting of 1152 PbWO4 crystals and 576 lead glass blocks for the PrimEx experiment at the Jefferson Laboratory. The detector was built for high precision measurement of the neutral pion lifetime via the Primakoff effect. Calorimeter installation and commissioning was completed with the first physics run in fall of 2004. We present the energy and position resolution of the calorimeter. Obtained {pi}0 mass resolution of 1.3MeV/c2 and its production angle resolution of 0.34mrad demonstrate the ability of the experiment to extract the {pi}0 lifetime on one percent level.

OSTI ID:
20891907
Journal Information:
AIP Conference Proceedings, Vol. 867, Issue 1; Conference: 12. international conference on calorimetry in high energy physics, Chicago, IL (United States), 5-9 Jun 2006; Other Information: DOI: 10.1063/1.2396938; (c) 2006 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
Country of Publication: