Imaging Thomson scattering has been implemented on the Omega Laser facility at the Laboratory for Laser Energetics, University of Rochester [J. M. Soures et al., Laser and Particle Beams 11, 317 (1993)]. Using a high-resolution spectrometer and an intensified charge-coupled device, the electron temperature profile, ranging from 1.5 to 3 keV, was measured along the axis of a CH gas-filled hohlraum. The system integrates over 200 ps a region 2 mm in length and has a spatial resolution of 50 {mu}m and a spectral resolution of 0.027 nm. Data obtained from this diagnostic are compared to hydrodynamic simulations.

OSTI ID:
20861227
Journal Information:
Review of Scientific Instruments, Vol. 77, Issue 10; Other Information: DOI: 10.1063/1.2220077; (c) 2006 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748