Title: Calibration of the sub-aperture backscatter system on OMEGA EP

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/5.0101839· OSTI ID:1988225

The sub-aperture backscatter (SABS) diagnostic on the OMEGA EP Laser System is a diagnostic that is used to measure the backscattered and sidescattered light during laser–plasma interaction experiments that are relevant to high-energy-density physics and inertial confinement fusion. The diagnostic collects stimulated Brillouin scattering (SBS) UV light at around 351 nm and stimulated Raman scattering (SRS) in the visible-light regime in the 420–720-nm-wavelength range and provides spectrally and temporally resolved information. Five 1-in. light collectors, composed of a lens, ground glass diffuser, and coupling into a 300-μm fiber, are positioned behind the last steering mirror on one of the four beamlines to catch a portion of the beam cross section (~1.5%) of the emission that is scattered into the beamline. The SRS light is collected in two light collectors, combined, and transported via graded index fibers to a streaked spectrometer. The SABS-SRS streak spectrometer has a temporal and spectral resolution of 100 ps and 1 nm, respectively. Three other light collectors collect, combine, and transport the SBS signal to a Hamamatsu high-voltage photodiode, where an oscilloscope digitizes the data, providing a time resolution of better than 1 ns. To obtain an absolute energy calibration of SRS measurements, light signals of known energy and wavelength were injected into the light collectors one at a time. The resulting counts on the streak camera charge-coupled device for SRS are then correlated with the incident fluence of scattered light at the light collector in order to allow a quantitative assessment of streak camera sensitivity to determine the energy of the scattered light during experiments. The measurements were performed in situ from the light collectors to the detectors. Other offline measurements provided the transmission of the optics between the target chamber center and the light collectors.

Research Organization:
Univ. of Rochester, NY (United States). Lab. for Laser Energetics
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA); New York State Energy Research and Development Authority; University of Rochester
Grant/Contract Number:
NA0003856
OSTI ID:
1988225
Journal Information:
Review of Scientific Instruments, Vol. 94, Issue 5; Conference: 24. Topical Conference on High-Temperature Plasma Diagnostics, Rochester, NY (United States), 15-19 May 2022; ISSN 0034-6748
Publisher:
American Institute of Physics (AIP)Copyright Statement
Country of Publication:
United States
Language:
English

References (7)

The streak camera development program at LLE
  • Jaanimagi, Paul A.; Boni, Robert; Butler, D.
  • 26th International Congress on High-Speed Photography and Photonics, SPIE Proceedings https://doi.org/10.1117/12.602565
conference March 2005
Multiple-beam laser–plasma interactions in inertial confinement fusion journal May 2014
Origins and Scaling of Hot-Electron Preheat in Ignition-Scale Direct-Drive Inertial Confinement Fusion Experiments journal January 2018
The National Ignition Facility journal December 2004
Direct-drive laser fusion: status, plans and future
  • Campbell, E. M.; Sangster, T. C.; Goncharov, V. N.
  • Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, Vol. 379, Issue 2189 https://doi.org/10.1098/rsta.2020.0011
journal December 2020
Stimulated Raman scattering mechanisms and scaling behavior in planar direct-drive experiments at the National Ignition Facility journal April 2020
OMEGA experimental program and recent results
  • Seka, W.; Babushkin, A.; Boehly, T. R.
  • The 13th international conference on laser interactions and related plasma phenomena https://doi.org/10.1063/1.53541
conference January 1997