Title: Accelerated screening methods for determining chemical and thermal stability of refreigerant-lubricant mixtures. Part II: Experimental comparison and verification of methods. Final report, volume I

Technical Report ·
DOI:https://doi.org/10.2172/196493· OSTI ID:196493
 [1]
  1. Univ. of Dayton Research Institute, Dayton, OH (United States)

The research reported herein was performed to develop an accelerated screening method for determining the chemical and thermal stabilities of refrigerant/lubricant mixtures. The developed screening method was designed to be safe and to produce accelerated stability rankings that are in agreement with the rankings determined by the current test, Sealed Glass Tube Method to Test the Chemical Stability of Material for Use Within Refrigerant Systems, ANSI/ASHRAE Method 97-1989. The accelerated screening test developed was designed to be independent of refrigerant and lubricant compositions and to be used with a wide variety of construction materials. The studied refrigerants included CFC-11, CFC-12, HCFC-22, HFC-134a, and HFC-32/HFC-134a (zeotrope 30:70 by weight). The studied lubricants were selected from the chemical classes of mineral oil, alkylbenzene oil, polyglycols, and polyolesters. The work reported herein was performed in three phases. In the first phase, previously identified thermal analytical techniques were evaluated for development into an accelerated screening method for refrigerant/lubricant mixtures. The identified thermal analytical techniques used in situ measurements of color, temperature, or conductivity to monitor the degradation of the heated refrigerant/lubricant mixtures. The identified thermal analytical techniques also used catalysts such as ferric fluoride to accelerate the degradation of the heated refrigerant/lubricant mixtures. The thermal analytical technique employing in situ conductivity measurements was determined to be the most suitable for development into an accelerated screening method.

Research Organization:
Air-Conditioning and Refrigeration Inst., Arlington, VA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
FG02-91CE23810
OSTI ID:
196493
Report Number(s):
DOE/CE/23810-41-Vol.1; ON: DE96006074; TRN: 96:001767
Resource Relation:
Other Information: PBD: Sep 1995
Country of Publication:
United States
Language:
English