Title: Helium Pot System for Maintaining Sample Temperature after Cryocooler Deactivation

Conference ·
DOI:https://doi.org/10.1063/1.2202411· OSTI ID:15020299

A system for maintaining a sample at a constant temperature below 10K after deactivating the cooling source is demonstrated. In this system, the cooling source is a GM cryocooler that is joined with the sample through an adaptor that consists of a helium pot and a resistive medium. Upon deactivating the cryocooler, the power applied to a heater located on the sample side of the resistive medium is decreased gradually to maintain an appropriate temperature rise across the resistive medium as the helium pot warms. The temperature is held constant in this manner without the use of solid or liquid cryogens and without mechanically disconnecting the sample from the cooler. Shutting off the cryocooler significantly reduces sample motion that results from vibration and expansion/contraction of the cold head housing. The reduction in motion permits certain processes that are very sensitive to sample position stability, but are not performed throughout the duration that the sample is at low-temperature. An apparatus was constructed to demonstrate this technique using a 4K GM cryocooler. Experimental and theoretical predictions indicate that when the helium pot is pressurized to the working pressure of the cryocooler's helium supply, a sample with continuous heat dissipation of several-hundred milliwatts can be maintained at 7K for several minutes when using an extension that increases the cold head length by less than 50%.

Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
15020299
Report Number(s):
UCRL-CONF-209416; TRN: US200519%%354
Resource Relation:
Journal Volume: 823; Conference: Presented at: 2005 Cryogenic Engineering Conference and International Cryogenic Materials Conference, Keystone, CO, United States, Aug 29 - Sep 02, 2005
Country of Publication:
United States
Language:
English

Similar Records

A cryocooler cooled 6T NbTi superconducting magnet with room temperature bore of 220mm
Journal Article · Mon Jul 01 00:00:00 EDT 1996 · IEEE Transactions on Magnetics · OSTI ID:15020299

NOVEL CRYOGENIC ENGINEERING SOLUTIONS FOR THE NEW AUSTRALIAN RESEARCH REACTOR OPAL
Journal Article · Sun Mar 16 00:00:00 EDT 2008 · AIP Conference Proceedings · OSTI ID:15020299

Tests of a GM Cryocooler and high Tc leads for use on the ALS superbend magnets
Conference · Fri Jul 09 00:00:00 EDT 1999 · OSTI ID:15020299