THE RHIC INJECTION SYSTEM.
Conference
·
OSTI ID:15016623
The RHIC injection system has to transport beam from the AGS-to-RHIC transfer line onto the closed orbits of the RHIC Blue and Yellow rings. This task can be divided into three problems. First, the beam has to be injected into either ring. Second, once injected the beam needs to be transported around the ring for one turn. Third, the orbit must be closed and coherent beam oscillations around the closed orbit should be minimized. We describe our solutions for these problems and report on system tests conducted during the RHIC Sextant test performed in 1997. The system will be fully commissioned in 1999.
- Research Organization:
- BROOKHAVEN NATIONAL LABORATORY (US)
- Sponsoring Organization:
- USDOE Office of Energy Research (ER) (US)
- DOE Contract Number:
- AC02-98CH10886
- OSTI ID:
- 15016623
- Report Number(s):
- BNL-66006; R&D Project: RC1000; KB0202000; TRN: US0502719
- Resource Relation:
- Conference: 1999 PARTICLE ACCELERATOR CONFERENCE, NEW YORK, NY (US), 03/29/1999--04/02/1999; Other Information: PBD: 29 Mar 1999