skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: American Water Heater Company: Compressed Air System Optimization Project Saves Energy and Improves Production at Water Heater Plant

Technical Report ·
DOI:https://doi.org/10.2172/15006012· OSTI ID:15006012

In 2001, American Water Heater Company implemented a system-level improvement project on the compressed air system that serves its manufacturing plant in Johnson City, Tennessee. The plant now operates with less compressor capacity, which has reduced its energy consumption and maintenance needs. The project's total cost was $228,000. The annual compressed air energy savings (2,345,000 kWh) and maintenance savings total $160,000, yielding a simple payback of 17 months. Furthermore, the system now supports the plant's production processes more effectively, which has improved product quality and increased production.

Research Organization:
National Renewable Energy Laboratory (NREL), Golden, CO (United States)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC36-99-GO10337
OSTI ID:
15006012
Report Number(s):
DOE/GO-102003-1716; TRN: US200402%%301
Resource Relation:
Other Information: PBD: 1 Nov 2003; Related Information: Industrial Technologies Program BestPractices Case Study (Brochure)
Country of Publication:
United States
Language:
English