skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Proton Transfer Reaction Ion Trap Mass Spectrometer

Journal Article · · Rapid Communications in Mass Spectrometry, 17(14):1593-1599
DOI:https://doi.org/10.1002/rcm.1088· OSTI ID:15004147

Proton Transfer Reaction Mass Spectrometry (PTR-MS) is a relatively new field that has attracted a great deal of interest in the last several years. This technique uses H3O+ as a chemical ionization (CI) agent for measuring volatile organic compounds (VOCs) in the parts per billion by volume (ppbv) - parts per trillion by volume (pptv) range. PTR-MS mass spectra are simple because the ionization method of proton transfer is “soft”, resulting in little or no fragmentation. Unfortunately, the simplicity of the mass spectra can cause problems in peak identification due to isobaric interferences. A possible solution to this problem is to couple the PTR drift tube to an ion trap mass spectrometer (ITMS). ITMS is appealing because of the ability to perform MS/MS and possibly distinguish between isomers and other isobars. Additionally, the ITMS duty cycle is much higher than that of a linear quadrupole so faster data acquisition rates can be realized for detection of multiple compounds. We present here the first results from a Proton Transfer Reaction Ion Trap Mass Spectrometer (PTR-ITMS). The aim of this study was to investigate ion injection and storage efficiency of a simple prototype interface in order to estimate possible detection limits of a second generation instrument. Using this prototype a detection limit of 100 ppbv was demonstrated for the PTR-ITMS. Modifications are suggested that will enable further reduction in detection limits to the low ppbv to pptv range. Furthermore the applicability of MS/MS to differentiate between isobaric species was determined. MS/MS spectra of the isobaric compounds methyl vinyl ketone (MVK) and methacrolein (MACR) are presented and show fragments of different mass making a differentiation possible even when a mixture of both species is present in the same sample. MS/MS spectra of acetone and propanal produce fragments with the same molecular weight but different ratios, allowing quantitative distinction only if one species is predominant. Fragmentation mechanisms are proposed to explain the results.

Research Organization:
Pacific Northwest National Laboratory (PNNL), Richland, WA (US), Environmental Molecular Sciences Laboratory (EMSL)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC06-76RL01830
OSTI ID:
15004147
Report Number(s):
PNNL-SA-38278; 2372; KP1303000
Journal Information:
Rapid Communications in Mass Spectrometry, 17(14):1593-1599, Journal Name: Rapid Communications in Mass Spectrometry, 17(14):1593-1599
Country of Publication:
United States
Language:
English

Similar Records

Proton Transfer Reaction Ion Trap Mass Spectrometer
Journal Article · Wed Jun 11 00:00:00 EDT 2003 · Rapid Communications in Mass Spectrometry, 17(14):1593-1599 · OSTI ID:15004147

On-line Analysis of Organic Compounds in Diesel Exhaust Using a Proton Transfer Reaction Mass Spectrometer (PTR-MS)
Journal Article · Mon Aug 01 00:00:00 EDT 2005 · International Journal of Mass Spectrometry, 245(1-3):78-89 · OSTI ID:15004147

Detecting Isobaric VOCs
Journal Article · Mon Sep 01 00:00:00 EDT 2003 · Analytical Chemistry, 75(17):371A · OSTI ID:15004147