Title: EE-3A Logging Report for April 5th., 1994

Technical Report ·
DOI:https://doi.org/10.2172/1248152· OSTI ID:1248152
 [1]
  1. Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

A Temperature/Casing-Collar Locator (CCL) log of EE-3A was performed on Tuesday, April 5th., 1994. This log was the second of two, (the first was run on February 28th., 1994.), in an attempt to investigate a temperature anomaly occurring between 10,000 to 11,435 ft. The thermal recovery of this zone was slower than expected, which was believed to be caused by either; flow through the cemented zone of the 5 1/2" liner, or an upward flow through the reservoir itself. After the first log was run, the annulus of EE-3A was shut-in for a period of a little more than one month, at which time the log was repeated. If the temperature of this zone were to show signs of recovery after the shut-in period, the integrity of the cement would have been in question. No sign of recovery would point to upward reservoir flow theory. The zone of interest shows no sign of recovery during the shut-in period.

Research Organization:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC52-06NA25396
OSTI ID:
1248152
Report Number(s):
LA-UR-15-29165-01
Country of Publication:
United States
Language:
English

Similar Records

EE-3A Logging Report for Feb. 28th., 1994
Technical Report · Mon Mar 14 00:00:00 EST 1994 · OSTI ID:1248152

Logging Report for April 19th., and 20th., 1994, Temp/CCL Logs of EE-3A
Technical Report · Wed Apr 27 00:00:00 EDT 1994 · OSTI ID:1248152

Post Expt. 2074 Temperature Log in EE-2A
Technical Report · Fri Jan 29 00:00:00 EST 1988 · OSTI ID:1248152