This paper shows the main differences between the COMMARA-2.0 and COMMARA-2.1 evaluated covariance data in the uncertainty estimation of integral parameters of interest for a large number of typical innovative fast neutron systems. The study provides some guidelines to the nuclear data evaluators on which materials and which reaction types need to be evaluated most accurately to achieve reliable results in computational analyses of similar systems. The assessment of the quality and reliability of the covariance data is outside the scope of the study.