S0 Tight Loop Studies on ICHIRO 9-Cell Cavities
Conference
·
OSTI ID:1115727
- KEK
- Fermilab
- JLAB
We have continued high gradient R&D of ICHIRO 9-cell cavities at KEK. ICHIRO 9-cell cavity #5 (I9#5) that has no end groups on beam tube to focus on high gradient sent to Jlab as S0 tight loop study. Surface treatments and vertical test were repeated 3 times at Jlab, and then I9#5 sent back to KEK. We also repeated surface treatments and test at KEK. Maximum gradients were 36.5MV/m at Jlab, and 33.7MV/m at KEK so far. Now we are struggling with the puzzle why the results of singles do not work well on 9-cell cavities.