Development of n-on-p Silicon Sensors for Very High Radiation Environments
We have developed a novel and highly radiation-tolerant n-in-p silicon microstrip sensor for very high radiation environments such as in the Super Large Hadron Collider. The sensors are designed for a fluence of 1 x 10{sup 15} neq/cm{sup 2} and are fabricated from p-type, FZ, 6 in. (150 mm) wafers onto which we lay out a single 9.75 cm x 9.75 cm large-area sensor and several 1 cm x 1 cm miniature sensors with various n-strip isolation structures. By evaluating the sensors both pre- and post-irradiation by protons and neutrons, we find that the full depletion voltage evolves to approximately 800 V and that the n-strip isolation depends on the p{sup +} concentration. In addition, we characterize the interstrip resistance, interstrip capacitance and the punch-through-protection (PTP) voltage. The first fabrication batch allowed us to identify the weak spots in the PTP and the stereo strip layouts. By understanding the source of the weakness, the mask was modified accordingly. After modification, the follow-up fabrication batches and the latest fabrication of about 30 main sensors and associated miniature sensors have shown good performance, with no sign of microdischarge up to 1000 V.
- Research Organization:
- Brookhaven National Lab. (BNL), Upton, NY (United States)
- Sponsoring Organization:
- DOE - OFFICE OF SCIENCE
- DOE Contract Number:
- DE-AC02-98CH10886
- OSTI ID:
- 1034031
- Report Number(s):
- BNL-96098-2011-JA; NIMAER; KA-04; TRN: US1200699
- Journal Information:
- Nuclear Instruments and Methods in Physics Research, Section A, Vol. 636, Issue 1; ISSN 0168-9002
- Country of Publication:
- United States
- Language:
- English
Similar Records
Testing of Surface Properties Pre-Rad and Post-Rad of n-in-p Silicon Sensors for Very High Radiation Environment
First bulk and surface results for the ATLAS ITk Strip stereo annulus sensors