Measurements of excess heat from a Pons-Fleischmann type electrolytic cell using palladium sheet
Two pieces of palladium sheet were loaded with deuterium in a Pons-Fleischmann type electrolytic cell and measurements were made of heat production. One sheet produced a steady increase in excess power that reached 7.5 watts (20% of input power) before the study was interrupted. A second similar sheet from a different batch of palladium did not produce any measurable excess power. There was a difference between the loading behavior, the maximum stoichiometry, and the presence of excess volume in the deuteride made from these materials. The first sheet contained 0.8% excess volume after deloading from D/Pd=0.82 to D/Pd=0.73, and the second sheet contained 13.5 % excess volume while at D/Pd=0.75. The high excess volume in the latter case is an indication of internal cracks.
- Research Organization:
- Los Alamos National Lab., NM (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-7405-ENG-36
- OSTI ID:
- 10171169
- Report Number(s):
- LA-UR-92-2390; CONF-9210151-1; ON: DE92018604
- Resource Relation:
- Conference: 3. cold fusion technology conference,Nagoya (Japan),21-25 Oct 1992; Other Information: PBD: [1992]
- Country of Publication:
- United States
- Language:
- English
Similar Records
Measurements of excess heat from a Pons-Fleischmann-type electrolytic cell using palladium sheet
The Fleischmann-Pons phenomenon; Different perspective
Related Subjects
73 NUCLEAR PHYSICS AND RADIATION PHYSICS
74 ATOMIC AND MOLECULAR PHYSICS
COLD FUSION
ELECTROLYTIC CELLS
CALORIMETRY
PALLADIUM
TESTING
TEMPERATURE MEASUREMENT
ELECTROLYTES
HEAVY WATER
CALIBRATION
700360
663440
664000
FUSION REACTIONS
D-, T-, AND HE-INDUCED REACTIONS AND SCATTERING
ATOMIC AND MOLECULAR PHYSICS