skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Tank Z-361 dose rate calculations

Technical Report ·
DOI:https://doi.org/10.2172/10148949· OSTI ID:10148949

Neutron and gamma ray dose rates were calculated above and around the 6-inch riser of tank Z-361 located at the Plutonium Finishing Plant. Dose rates were also determined off of one side of the tank. The largest dose rate 0.029 mrem/h was a gamma ray dose and occurred 76.2 cm (30 in.) directly above the open riser. All other dose rates were negligible. The ANSI/ANS 1991 flux to dose conversion factor for neutrons and photons were used in this analysis. Dose rates are reported in units of mrem/h with the calculated uncertainty shown within the parentheses.

Research Organization:
Fluor Daniel Hanford, Inc., Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States); USDOE Assistant Secretary for Nuclear Energy, Washington, DC (United States)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
10148949
Report Number(s):
HNF-3361; ON: DE99050809; BR: 1K6A0D010; TRN: AHC29927%%258
Resource Relation:
Other Information: PBD: 30 Sep 1998
Country of Publication:
United States
Language:
English