Tank Z-361 dose rate calculations
Neutron and gamma ray dose rates were calculated above and around the 6-inch riser of tank Z-361 located at the Plutonium Finishing Plant. Dose rates were also determined off of one side of the tank. The largest dose rate 0.029 mrem/h was a gamma ray dose and occurred 76.2 cm (30 in.) directly above the open riser. All other dose rates were negligible. The ANSI/ANS 1991 flux to dose conversion factor for neutrons and photons were used in this analysis. Dose rates are reported in units of mrem/h with the calculated uncertainty shown within the parentheses.
- Research Organization:
- Fluor Daniel Hanford, Inc., Richland, WA (United States)
- Sponsoring Organization:
- USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States); USDOE Assistant Secretary for Nuclear Energy, Washington, DC (United States)
- DOE Contract Number:
- AC06-96RL13200
- OSTI ID:
- 10148949
- Report Number(s):
- HNF-3361; ON: DE99050809; BR: 1K6A0D010; TRN: AHC29927%%258
- Resource Relation:
- Other Information: PBD: 30 Sep 1998
- Country of Publication:
- United States
- Language:
- English
Similar Records
Tank 241-Z-361 Sludge Retrieval and Treatment Alternatives
PFP vertical calciner shield wall dose rate calculations using MCNP
Tank 241-Z-361 process and characterization history
Technical Report
·
Wed May 24 00:00:00 EDT 2000
·
OSTI ID:10148949
PFP vertical calciner shield wall dose rate calculations using MCNP
Technical Report
·
Thu Aug 21 00:00:00 EDT 1997
·
OSTI ID:10148949
Tank 241-Z-361 process and characterization history
Technical Report
·
Thu Aug 06 00:00:00 EDT 1998
·
OSTI ID:10148949